21.9.2026

Why does the pneumatic transport pipeline become clogged and how can the problem be solved?

A pneumatic conveying pipeline is a closed and clean way to transport powdered and granular bulk materials in industrial processes. When the system is operating properly, it is reliable and virtually maintenance-free. But sometimes the pipeline gets clogged, and then production stops. In this guide, we’ll go through what causes the clogging, how to locate the problem, how to safely open the pipeline, and how to prevent the problem from recurring.

If you are wondering which pneumatic conveying system would best suit your process, please take a look at to our pneumatic transport solutions before I delved into this guide.

Most common causes of blockage in pneumatic transport

The blockage of pneumatic transport does not usually occur suddenly. There is almost always some identifiable reason behind it, which has developed over time or emerged as a result of a single operational error situation. Understanding the blockage begins with identifying the most common root causes.

The most common reason is too low air velocity in the pipeline. When the flow rate of the gas drops below the minimum required speed for material transport, the material begins to accumulate at the bottom of the pipe. This is particularly common in dilute phase conveying, where high speed is a prerequisite for maintaining material flow.

Other common reasons include:

  • Rise in the material's moisture content: The wet material adheres to the pipe walls and forms deposits that narrow the flow orifice.
  • Incorrect material feed speed: Too large a volume of material relative to the air flow strains the tube and leads to blockage.
  • Pipework geometry A steep bend, a curvature radius that is too small, or a rise that follows a horizontal section are risk factors where the material accumulates more readily.
  • Components that have worn out or are damaged: A leaking ball valve or worn-out feed device changes the pressure balance and impairs the transport capacity.
  • Change in material properties: If the raw material’s bulk density, flow properties, or other characteristics change, the previously functioning control system is no longer sufficient.

In dense phase conveying, the risk of blockage is different. Since the material moves through the pipe more slowly as a bubble, blockage usually occurs when the length of the bubble becomes too large or the pressure is insufficient to move it forward. This can be caused by a pressure source capacity problem or a pipeline leak.

This is how you diagnose the location and severity of the blockage

Before taking any action, find out where the blockage is located and how serious it is. Acting hastily can complicate the situation or cause a dangerous situation. A good diagnosis saves time and effort.

  1. Check the pressure meter readings throughout the entire pipeline. An abnormal increase in pressure at a certain point or a loss of pressure at the end of the pipeline indicates the direction of the blockage.
  2. Listen to the tube with your hands or with a stethoscope. The clogged pipe does not make any sound when flowing, while in the partially blocked area there may be an uneven noise.
  3. Rock the tube with a metal object evenly. A full or clogged duct sounds dark and full, a hollow tube gives a brighter sound.
  4. Visually inspect all the bends, turns and bottom ends of the vertical sections. These are the most typical support points.

Once you have located the approximate location of the blockage, assess its severity. A mild blockage may open with the right pressure pulse, but a hard or hardened buildup of material requires mechanical action. If the pressure rises rapidly and does not subside, the blockage is likely complete and requires immediate action.

If blockages occur repeatedly in the same location, write down the location. A recurring blockage is a sign of a structural problem that needs to be fixed permanently, not just opened again every time.

Opening the blocked pipe safely step by step

Opening a blocked pneumatic transport pipeline requires caution. The pipeline may have residual pressure, and the material can leak out uncontrollably if the action is undertaken without proper preparation.

  1. Stop the system and isolate the piping from the pressure. Close all the feed valves and ensure that the air supply has been cut off. Wait until the pressure has completely released before touching the tube.
  2. Mark the danger zone. Prevent unauthorized persons from entering the area where the pipe is being opened.
  3. Try pressure pulsation first. In many systems, it is possible to apply short pressure spikes at the rear of the support point. This can detach the lightweight support without mechanical intervention.
  4. If the pulsation does not help, open the plumbing cleaning valve or the removable connection closest to the blockage. Do this slowly and use protective equipment, as the residual material may splash out.
  5. Remove the material mechanically. Use a cleaning tube or a flexible cleaning tool. Do not use sharp objects that could damage the inner surface of the tube.
  6. Check the inner surface of the tube after opening it. Look for signs of wear, cracks, or corrosion that could explain the blockage or predict future problems.
  7. Close the tube and perform a tightness test before restarting. Make sure all connections are tight before you re-pressurize the system.

Once the pipeline is opened and closed, start the system at low capacity and monitor the pressure gauges for the first few minutes. Normal, stable pressure readings indicate that the transport is functioning correctly again. If the pressure rises abnormally immediately after starting, the blockage has not been completely removed, or the problem is elsewhere in the pipeline.

Do you want to ensure that your system is properly sized for the future? Contact our experts, So we’ll go through the situation together.

Prevention of jamming with the correct system regulation

The best way to deal with blockages is to prevent them completely. Most recurring blockage problems are caused by the fact that the system parameters do not match the actual properties of the material being transported. Proper adjustment is an ongoing process, not a one-time action.

Start by checking the following parameters regularly:

  • Air speed and pressure: Make sure that the transport speed remains within the appropriate range for the material. In the case of a roller conveyor, the speed must not fall below the minimum value, while in the case of a tube conveyor, too high a speed will wear out the tube and damage the material unnecessarily.
  • Feed speed: The amount of material fed must be balanced with the air flow. Too rapid feeding is one of the most common causes of clogging.
  • Material moisture: Monitor the moisture content of the material, especially if the raw material delivery quantities vary or storage conditions change.
  • Condition of components: Check the valves, feeding equipment, and pipe connections at regular intervals. Even a small leak changes the pressure balance and increases the risk of blockage.

In addition, it is worth utilizing the system’s own diagnostic data. The modern pneumatic transport system collects data on pressure, flow, and cycle times. Deviations in these values often predict blockage before it occurs. Trend monitoring helps identify when any component starts to wear out or the material properties have changed.

A well-designed and properly adjusted pneumatic conveying system can operate for years without significant clogging problems. If clogging still occurs repeatedly, the fault is almost always either in the design, the changed properties of the material, or in worn components. There are solutions for all of these, as long as the problem is identified in time.

Kopar has designed and supplied pneumatic conveying systems for demanding industrial processes for almost 50 years. Learn more to our references and see what kinds of challenges we have found solutions for. You can also read more about it, Which pneumatic conveyor is best suited for fine-grained materials.

If you want to assess the functionality of your system or map out the possibilities for updates, Get in touch and tell us about your situation. We will help you find a solution that fits your specific process.

Kopar Service Manager

You have a challenge that needs solving?