{"id":12327,"date":"2026-10-29T08:00:00","date_gmt":"2026-10-29T06:00:00","guid":{"rendered":"https:\/\/kopar.fi\/?p=12327"},"modified":"2026-08-20T14:46:25","modified_gmt":"2026-08-20T11:46:25","slug":"how-do-circular-materials-affect-the-structure-of-the-industrial-shredder","status":"publish","type":"article","link":"https:\/\/kopar.fi\/en\/miten-kierratysmateriaalit-vaikuttavat-teollisuusjaahdyttimen-rakenteeseen\/","title":{"rendered":"How do recycled materials affect the structure of an industrial chiller?"},"content":{"rendered":"<p>Recycled materials place demands on the industrial chiller that traditional design does not always recognize. The material can be hot, wet, fine-grained, corrosive, or all of these at the same time, and these characteristics directly affect how a structure will function reliably and how it will not. In this guide, we will go through how the structure of the chiller should be designed with recycled material conditions in mind, step by step.<\/p>\n<p>If you are planning a cooling solution for the circular economy process, <a href=\"https:\/\/kopar.fi\/en\/cooling\/\">Explore our cooling solutions<\/a> and see what different apps are available.<\/p>\n<h2>Find out the material properties before planning<\/h2>\n<p>Determine the true properties of the material before making any structural decisions. Recycling materials, such as scrap from the steel industry, waste material from the lead-acid battery industry, or process waste from accumulator materials, do not have established reference values in the same way as primary raw materials. Their composition, particle size, moisture, and temperature can vary from batch to batch, which makes preliminary mapping particularly important.<\/p>\n<p>For planning purposes, please collect at least the following information:<\/p>\n<ul>\n<li>Material inlet temperature and desired outlet temperature<\/li>\n<li>Particle size and size distribution<\/li>\n<li>Moisture content and possible hygroscopicity<\/li>\n<li>Durability and hardness<\/li>\n<li>Chemical composition, especially compounds that cause corrosion<\/li>\n<li>Capacity requirements in tons per hour<\/li>\n<\/ul>\n<p>Also check whether the material is prone to sintering, fluidization, or clogging at high temperatures. These phenomena are common, for example in hot furnaces and boilers, and they directly affect the proper operation of the internal geometry of the equipment. Incomplete data collection is one of the most common reasons why a chiller does not operate as expected after commissioning.<\/p>\n<p>If there is insufficient empirical knowledge about the material, at this stage it is worth considering a material test before the final sizing. We will return to this in more detail later on.<\/p>\n<h2>Choose structural solutions according to the requirements of the material<\/h2>\n<p>Choose the cooling system structure based on the material properties required, not on what is the most common or well-known solution. For recycled materials, there is often no ready-made, shelf-ready solution, so the design must start from the material's conditions.<\/p>\n<ol>\n<li><strong>Evaluate the required cooling technology<\/strong> based on the material\u2019s temperature and capacity. Extremely hot materials, such as bottom ash or metallurgical slag, require a high-performance solution that can withstand continuous thermal stress. Rotating coolers and cooling drums often perform better than traditional screw designs when temperatures are high and material wear is significant.<\/li>\n<li><strong>Measure the contact surfaces according to wear resistance<\/strong>. Recycled materials, such as scrap and process dust, can wear structures much faster than primary raw materials. Choose material thicknesses and coatings based on the actual wear profile.<\/li>\n<li><strong>Pay attention to the moisture in the structure<\/strong>. If the material is wet or it becomes compacted as it cools, the internal surfaces of the device must withstand the moisture load and no areas should form in the structure where the wet material gets stuck.<\/li>\n<li><strong>Ensure dust management<\/strong>. Fine-grained recycling materials, such as accumulator materials or process dust, require a closed structure and adequate sealing solutions. Open or poorly sealed equipment poses both a safety risk and material waste.<\/li>\n<li><strong>Plan the interfaces into the process<\/strong>. Check what equipment is located in front of and behind the cooler, and ensure that the material flow runs smoothly throughout the entire chain without any bottlenecks.<\/li>\n<\/ol>\n<p>You can verify the correctness of structural choices by comparing the selected solution to the most critical properties of the material. If the material is highly hot and wear-prone, the cost of maintaining the equipment and reliability of operation are key metrics. A modular design, where wear parts can be replaced without dismantling the entire equipment, is often the most practical choice in demanding circular economy applications.<\/p>\n<p>Would you like to discuss which structure is suitable for your material? <a href=\"https:\/\/kopar.fi\/en\/contact\/\">Contact us<\/a> and we'll go over the situation together.<\/p>\n<h2>Ensure functionality by testing before deployment<\/h2>\n<p>Test the material\u2019s behavior under test conditions before final sizing and installation. This step is particularly important when the material is a new by-product with no previous operating experience. Recycled materials tend to behave in surprising ways when subjected to the mechanical and thermal stresses of the cooling system.<\/p>\n<p>During the testing phase, it is worth investigating at least the following things:<\/p>\n<ul>\n<li>How does the material behave at high temperatures: does it sinter, does it fluidify, or does it form lumps in it?<\/li>\n<li>How quickly does the material wear down the surfaces of the test equipment?<\/li>\n<li>Will the desired output temperature be reached within the planned time period?<\/li>\n<li>How does humidity affect the material flow in the device?<\/li>\n<\/ul>\n<p>Based on the test results, you can verify the dimensioning and make the necessary adjustments before the device is manufactured into its final configuration. This reduces the risks associated with commissioning and significantly improves the operational reliability of the overall solution. For example, in the handling of chip debris and various metal dusts, pre-testing has proven valuable: the material\u2019s actual behavior often deviates from theoretical values in a way that directly affects the device\u2019s dimensioning.<\/p>\n<p>You can also get acquainted with <a href=\"https:\/\/kopar.fi\/en\/references\/\">to our references<\/a> and see what kinds of applications similar solutions have been implemented for.<\/p>\n<h2>Consider maintainability and versatility in the long term<\/h2>\n<p>Design the chiller so that it is easy to maintain and, if necessary, adapt to changing process conditions. The composition and properties of recycled materials can change over time, for example as raw material flows change or process technology develops. A device designed for only one precisely defined material may be difficult to adapt to this.<\/p>\n<p>Structural solutions that are essential for maintainability include:<\/p>\n<ul>\n<li><strong>Removable wear surfaces<\/strong>, These can be replaced without having to disassemble the entire device. This reduces maintenance downtime and significantly reduces maintenance costs.<\/li>\n<li><strong>Changeability of panels or parts<\/strong> such that worn parts can be recycled with each other to equalize wear before the final exchange.<\/li>\n<li><strong>Easy access to the interior parts<\/strong> for inspections and cleaning without special tools or long downtimes.<\/li>\n<li><strong>Modular structure<\/strong>, which allows for capacity to be increased or technical changes to be made without having to replace the entire device.<\/li>\n<\/ul>\n<p>Adaptability is particularly important in circular economy applications where processes evolve and new by-products are introduced. A device that was originally designed for a specific type of waste may later process different materials, and this must be able to be taken into account without requiring large investments.<\/p>\n<p>Long-term maintenance cooperation with the supplier supports the reliable operation of the equipment throughout its entire life cycle. Not everything can be predicted on the design table, and the actual behavior of the material often only becomes apparent after commissioning. In such cases, it is important that the solution can also be developed together after commissioning.<\/p>\n<p>Kopar designs and supplies cooling solutions for the most demanding applications in the circular economy, from hot metallurgical billets to fine-grained process dust. <a href=\"https:\/\/kopar.fi\/en\/cooling\/\">Discover our cooling solutions<\/a> or <a href=\"https:\/\/kopar.fi\/en\/contact\/\">Get in touch<\/a>, So let\u2019s go through together what kind of solution would suit your process exactly.<\/p>","protected":false},"excerpt":{"rendered":"<p>Recycled materials challenge cooling-fan design. Read how to choose the right material for the structure.<\/p>","protected":false},"featured_media":5163,"menu_order":0,"template":"","class_list":["post-12327","article","type-article","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/kopar.fi\/en\/wp-json\/wp\/v2\/article\/12327","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kopar.fi\/en\/wp-json\/wp\/v2\/article"}],"about":[{"href":"https:\/\/kopar.fi\/en\/wp-json\/wp\/v2\/types\/article"}],"version-history":[{"count":1,"href":"https:\/\/kopar.fi\/en\/wp-json\/wp\/v2\/article\/12327\/revisions"}],"predecessor-version":[{"id":12349,"href":"https:\/\/kopar.fi\/en\/wp-json\/wp\/v2\/article\/12327\/revisions\/12349"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kopar.fi\/en\/wp-json\/wp\/v2\/media\/5163"}],"wp:attachment":[{"href":"https:\/\/kopar.fi\/en\/wp-json\/wp\/v2\/media?parent=12327"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}